HVAC Installation Works in Hypermarket
We have done installation & commissioning of 900 TR HVAC System for a major client. The project had 3 Chillers, 8 Pumps, 20 AHUs, 98 FCUs & other associated equipments.
Our specialist team executed supply, installation, testing and commissioning of 119 nos. ducted split, 120 nos. floor standing unit and 15 nos. rooftop package unit with a total installed capacity of 1461 TR to provide wild air cooling for a 2B+G+64 storey multi purpose building in downtown Dubai.
Commercial Building at Madinat Al Irfan
We have supplied 53 AHUs, 2 FAHUs, 4 BCUs from UNTES Turkey, All units, except FAUS, are ceiling suspended type with special base frame arrangement. For this project 80 FCUs were supplied from Aermec Italy. Total installed low side capacity is 516 TR for this commercial building which is targeting L...
RDU for Ministry of Health Oman
Our team has designed and commissioned chilled water system for multiple renal dialysis unit across the Sultanate for Ministry of Health Oman. A total of 6 chiller plant, over 200 TR capacity ha sbeen supplied over last 2 years. The scope incuded supply, installation, testintg and com...
AHU Replacement at Al Husn Mess
We have supplied 3 air handling units (83.3TR) for Royal Guard of Oman at Al Husn Mess. The units were supplied in semi-knocked down condition from factory due to site constraint. The scope of works included ahu assembly, chilled water piping and insulation, ducting works, valve replacement, electri...
Our team designed, installed and commisioned chilled water plant for a process cooling requirement for one of the most prestigeous client's laundry at Mabela. Our integrated solution included supply, installation, testing and commissioning of one duty and one duty-assist chiller mounte...
We have done replacement of Chiller Plant with a capacity of 800 TR for ministry client in Oman. Project includes 4 Chillers, 5 Pumps & other associated equipments, with necessary piping & valve package replacement. the scope was carried out within minimum shutdown during the weekend.
HVAC Installation at Desalination Plant Ghubra
We have carried out complete supply, installation, testing and commissioning of air conditioning system for a Desalination plant Al Ghubra. 3 nos. of 30 TR Rooftop package unit is installed to cool the electrical plant room.
We have supplied one air handling unit (20 TR) in complete knocked-down condition (from factory) along with DDC panel for Grand Hyatt Muscat Hotel. The AHU was successfully assembled and commissioned by our team at site.
We supplied 3 units of Aermec NRB air-to-water heat pump reaching upto heating capacity of 590 kW and cooling capacity of 390kW to 5 star Chedi Resort in Ras Al Hadd, Oman. These heat pumps shall provide cooling and heating of 5 swimming pools, including a 100m long pool - the longes...